AC Power line N-PE applications
Class I and Class II Surge protection
Voltage : 600V
Up: <1500V
Uc: 260V
In: 40KA
Iimp: 8 KA
Imax: 65KA
Specification of H2R12-600VE |
||
Dc spark-over voltage (100V/s) 1) |
600V ±20% |
|
Maximum impulse spark-over voltage @ 1KV/μs2) |
1000V |
|
Breakdown time - typical values |
<100ns <20ns |
|
Insulation resistance @DC250V |
1000MΩ |
|
Class I according to IEC 61643-11 Max continuous operating voltage at 50/60 Hz Uc Nominal discharge current 8/20μs In Impulse current 10/350μs Iimp |
260V 40KA 8KA |
|
Class II according to IEC 61643-11 Max continuous operating voltage at 50/60 Hz Uc Nominal discharge current 8/20μs In Maximum discharge current 8/20μs Imax |
260V 40KA 65KA |
|
capacitance at 1MHz |
<1.5pF |
|
Weight |
~ 8g |
|
UL 1449 Certification On the UL List |
|
|
Delivery time |
20days |
|
Operation and storage temperature |
-40℃ … +90℃ |
|
Marking, Green
|
2R 600 YY |
600 - Nominal voltage YY - Year of production |